Thermal Vacuum Chamber MORABA

Thermal testing and chemical analysis of residual gas via mass spectrometer (Quadrex 200).

A circular copper plate with a pattern of threaded holes M6 is provided as base for the test setup in the TVC. The plate may be temperature controlled.

Features thermal:
Vacuum
Solar simulator
Thermal plate
Temperature controlled shroud
Specimen width/dia [mm]: 1350.0
Specimen height/thk [mm]: 1400.0
Higher temperature [K]: 353.0
Lower temperature [K]: 203.0
Temperature change rate [±K/min]: 1.0
Feedthroughs: Gaseous material: Swagelog; Signal and current: D-sub (15 -50), Lemo, Deutsch, coaxial SMA, BNC and TNC; other feedthroughs on request
Data acquisition: ALMEMO® data logger
Vacuum limit [hPa] [mbar]: 1*10^-5
Certification:
ISO/IEC 17025
ISO 9001
AS/EN/JISQ 9100
Keywords: Thermal Vacuum Chamber, TVC, temperature profile, mass spectrometer, DLR, MORABA