The vertically configured 6.5m diameter thermal vacuum cycling chamber (TVAC) chamber comes with an optical bench and Thermal Conditioning Units (GN2/LN2) from -196°C to 80°C, as well as with a He closed loop System for cryogenic applications (<20K).
Features thermal:
Vacuum
Solar simulator
Thermal plate
Temperature controlled shroud
Specimen length [mm]:
2956.0
Specimen width/dia [mm]:
6500.0
Higher temperature [K]:
393.0
Lower temperature [K]:
4.2
Temperature change rate [±K/min]:
2.0
Feedthroughs:
Deutsch, Sub-D, SMA
Data acquisition:
1 sample/min. Temperature sensors, pressure gauges, TQCM
Vacuum limit [hPa] [mbar]:
1e-06 mbar
Project heritage:
GAIA, Herschel Telescope, JUICE solar panels...
Cleanroom classes (ISO 14644-1):
ISO Class ≤5
ISO Class 6
ISO Class 7
ISO Class 8
ISO Class 9
Certification:
ISO/IEC 17025
ISO 9001
AS/EN/JISQ 9100
Keywords:
Optical Calibration, Thermal cycles, Thermal Balance, Bake-out