EMC Test Facility

The EMC Test Facility is used for electromagnetic compatibility measurements according ECSS-E-ST-20-07C, error/disturbance detection, error/disturbance localization, DC magnetic field emission, DC magnet moment.

Technical Parameters and practicable tests according ECSS-E-ST-20-07C:

• Conducted Emissions/Susceptibility: 30 Hz to 200 MHz

• Conducted Susceptibility Transients: 0.15 μs / 10 μs

• Radiated Emission: 10 kHz to 40 GHz

• Radiated Susceptibility: 30 MHz to 80 MHz at 10 V/m and 80 MHz to 6 GHz at 20 V/m

• ESD: up to 15 kV

Measurement of:

• in-rush current

• bonding resistors

• isolation resistors/capacitance

Specimen length [mm]: 4000.0
Specimen width/dia [mm]: 3000.0
Specimen height/thk [mm]: 3300.0
Keywords: EMC testing, Electromagnetic Compatibility, Conducted Emissions/Susceptibility, Conducted Susceptibility Transients, Radiated Emission, Radiated Susceptibility, ESD, DLR