The climate chamber allows an automatic simulation of different thermal and humidity environments.
Specimen length [mm]:
1100.0
Specimen width/dia [mm]:
1000.0
Specimen height/thk [mm]:
900.0
Higher temperature [K]:
453.15
Lower temperature [K]:
203.15
Highest rH [%]:
98.0
Lowest rH [%]:
10.0
Temperature change rate [±K/min]:
6.0
Data acquisition:
USB data logging, ethernet
Cleanroom classes (ISO 14644-1):
ISO Class ≤5
ISO Class 6
ISO Class 7
ISO Class 8
ISO Class 9
Certification:
ISO/IEC 17025
ISO 9001
AS/EN/JISQ 9100
Keywords:
TV, thermal cycling, ESA, ESTEC, Mechanical Systems Laboratory, MSL