Thermovacuum chamber enables thermal cycling in vacuum with constant vacuum value.
1. Large parts testing is available
2. Functional Tests could be performed during TV tests
3. Temperature range is sufficient for instruments during standard cosmic mission in Earth Orbit
4. Tests could be performed according to ESA ECSS standards
5. Excellent approach into the TV chamber from two opposite sides
6. TV chamber is located in the Clean room
Available standards (e.g. ASTM, MIL):
ECSS-E-ST-10-03, ECSS-Q-ST-70-04C
Features thermal:
Vacuum
Solar simulator
Thermal plate
Temperature controlled shroud
Specimen length [mm]:
950.0
Specimen width/dia [mm]:
850.0
Specimen height/thk [mm]:
800.0
Mass max. [kg]:
15.0
Higher temperature [K]:
403.15
Lower temperature [K]:
188.15
Temperature change rate [±K/min]:
2.0
Feedthroughs:
• D-Sub 5501-50SA-02-F1 • SMA coaxial • 8pins Power 15A
Vacuum limit [hPa] [mbar]:
10-7
Cleanroom classes (ISO 14644-1):
ISO Class ≤5
ISO Class 6
ISO Class 7
ISO Class 8
ISO Class 9