70-200 keV electron accelerator for component testing
The Risø HDRL low energy electron accelerator is used for irradiation of docimeters and samples.
- Beam current: 1-10 mA
- Conveyor tray speed: 3-30 m min-1
- Maximum sample size: 20 x 30 cm2
- Maximum sample height: 5 cm
- References: ISO/ASTM 51818:2013 Standard Practice for Dosimetry in an Electron Beam Facility for Radiation Processing at Energies Between 80 and 300 keV
Available standards (e.g. ASTM, MIL):
SO/ASTM 51818:2013 Standard Practice for Dosimetry in an Electron Beam Facility for Radiation Processing at Energies Between 80 and 300 keV
Features radiation:
Electron
Proton
Gamma
UV
Neutron
Heavy ion
Laser
Specimen length [mm]:
200.0
Specimen width/dia [mm]:
200.0
Specimen height/thk [mm]:
50.0
Certification:
ISO/IEC 17025
ISO 9001
AS/EN/JISQ 9100
Keywords:
E-beam electron irradiation keV 17025