VIBRATION TESTING

SCOPE:
Vibration testing of sinusoidal, broadband random, mixture (SoR, SoS) modes, mechanical shocks, and field replicated data
Combination of vibration and temperatures in climatic chambre in the range from -70°C to 180°C
Combination with high temperatures generated by gas burner, heat oven or induction-principle operating equipment up to 1100°C
Fatigue testing and life testing (Wöhler curves on shaker)
Frequency range from 5 Hz to 5000 Hz
Complete modules testing e.g. dashboard, front/rear bumper up to 800 kg

EQUIPMENT:
LDS 22kN with 1m3 Vötsch climatic chamber, slip table 600 x 600 mm
LDS 35kN with 1m3 Vötsch climatic chamber, slip table 900 x 900 mm
UDCO 30kN with 1m3 Vötsch climatic chambre, slip table 500 x 500 mm
DongLing 50kN with 2,2m3 Vötsch climatic chamber (1400 x 1400 x 1150 mm), slip table GT 500M - 500 x 500 mm, GT 900M - 900 x 900 mm
MADE 40kN with 1m3 Vötsch climatic chamber, slip table 600 x 600 mm
MADE 60kN with 16m3 ACS climatic chamber (with IR radiation function), chamber 2400 x 1700 x 2200 mm (9m3), slip table 2000 x
1500 mm

BENEFITS:
Design and production of test fixtures including CAE analyses
Contactless vibration measurement using single-channel vibrometer (Doppler)
Noise measurement using 1-4 microphones or acoustic field assessment using the acoustic camera (120 microphones) in silent chamber with 1.6kN shaker excitation (45dB limit)
Additional active simulation of car cooling system
Additional powering systems up to 1500V DC
DAQ – data logging up to 60 channels
CAN control systems
Consultancy services

STANDARDS:
ISO 16750-3, VW 80000, LV124,
IEC 60068-2-64; IEC 600068-2-6;
IEC 60068-2-27

Type: Service
Available standards (e.g. ASTM, MIL): ISO 16750-3, VW80000, LV124, IEC 60068-2, IEC 60068-2-6, IEC 60068-2-27
Features mechanical:
Sine
Random
Shock
Static load
Micro vibration
Acoustic
Specimen length [mm]: 7800.0
Specimen width/dia [mm]: 5300.0
Specimen height/thk [mm]: 4800.0
Mass max. [kg]: 800.0
Frequency min. [Hz]: 5.0
Frequency max. [Hz]: 5000
Data acquisition: DAQ system up to 48channels; sampling rate up to 1 MS/s
Certification:
ISO/IEC 17025
ISO 9001
AS/EN/JISQ 9100
Keywords: EMC ESD Radiated emmisions Conducted immunity