EMC Test Facility

In the EMC facility of the Tesat Spacecom GmbH & CO KG EMC tests according to MIL-STD 461 and ECSS-E-ST-20-07C can be performed.

Conducted Emission

  • Frequency Domain up to 500 MHz
  • Time Domain Measurements (Current: 100 MHz BW; Voltage 500 MHz BW)
  • Inrush Current / Initial Bus Application up to 200 A (arbitrary ramp or with fast switch rise time up to 5 V/ns)

Conducted Susceptibility

  • Sine Wave Injection up to 500 MHz (injection probe)
  • Arbitrary transients with falling and rising edge slopes up to 50 V/µs.
  • CS06: 10 µs, 5 µs, 150 ns

Radiated Emission

  • E-Field, up to 50 GHz (mixer measurements up to 110 GHz)
  • H-Field 30 Hz - 300 kHz

Radiated Susceptibility

  • E-Field: up to 50 GHz and 25 V/m
  • - 200 MHz - 18 GHz: 100V/m
  • - 18 GHz - 40 GHz: 50 V/m
  • H-Field: DC - 300 kHz

ESD-Test up to 20 kV and 100 A with different pulse shapes.

Available standards (e.g. ASTM, MIL): MIL-STD 461, ECSS-E-ST-20-07C, MIL-STD 462
Specimen length [mm]: 2000.0
Specimen width/dia [mm]: 2000.0
Specimen height/thk [mm]: 2000.0
Mass max. [kg]: 2000.0
Cleanroom classes (ISO 14644-1):
ISO Class ≤5
ISO Class 6
ISO Class 7
ISO Class 8
ISO Class 9
Certification:
ISO/IEC 17025
ISO 9001
AS/EN/JISQ 9100
Keywords: EMC, Electromagnetic Compatibility, Conducted Emissions, Conducted Susceptibility, Radiated Emission, Radiated Susceptibility, ESD, EMI