Combined Chamber

It is employed for combined vibration, humidity, temperature and altitude test.

Temperature accuracy in time: +/-1°C
Humidity range : [+10%, +95%]
RH accuracy (not less than +/-1°C on dew point difference): 3%
Dew point range: [+20, +94°C]
Altitude: up to 30 Km (P=1 mbar)
Vibration: Sine , Random (100g),Shock(200 g)
Frequency Range : DC – 3 kHz.

Data acquisition:
• LMS SCADAS III (90 chs + 4 exc ch)
• IMC CRONOS PL8 (60 chs)

Accredited test methods:
• ESA ECSS-E-10-03A
• MIL-STD-810-C / F / G
• RTCA DO -160D

The Combined Chamber is part of the Space Qualification Laboratory (LQS).
The LQS is a facility aimed at supporting aerospace companies in the design, manufacturing and testing of nano and micro satellites (up to 70 Kg) and electronic and mechanical components of space, avionic and military systems, providing service activities for the qualification and acceptance to mechanical and operational environmental loads. Test facilities and test procedures are in accordance with the most rigorous standard established by the European space Agency and military requirements.

Specimen length [mm]: 1010.0
Specimen width/dia [mm]: 1010.0
Specimen height/thk [mm]: 1020.0
Mass max. [kg]: 600.0
Higher temperature [K]: 393.15
Lower temperature [K]: 198.15
Temperature change rate [±K/min]: 5.0
Vacuum limit [hPa] [mbar]: 1
Cleanroom classes (ISO 14644-1):
ISO Class ≤5
ISO Class 6
ISO Class 7
ISO Class 8
ISO Class 9
Certification:
ISO/IEC 17025
ISO 9001
AS/EN/JISQ 9100
Keywords: CIRA, temperature, altitude, thermal, humidity, chamber, test, vibration